
Add to Cart
Final Drive Motor 172458-73700 172171-73700 For Yanmar VIO30-2 VIO35 VIO35-2 VIO35-3 VIO35-5 VIO35-5B Excavator Gearbox
Part Name | Final Drive |
Quality | 100% high test |
Brand | HUILIAN |
AppliCATEEEEEEion | Excavator |
Color | Customized |
Warranty | 6-12 months |
Packing | Standard |
MOQ | 1PC |
Final Drive Motor Model
Motor Brand | Motor Model |
NABTESCO | GM02 GM03 GM04 GM05 GM06 GM09 GM18 GM21 GM35 GM60 GM85 GM06VA GM07VC GM08 GM09VN GM10VA GM15 GM17 GM18VL GM20 GM21VA GM23 GM28 GM35VL GM38VB GM40VA GM45VA GM50VA GM60VA GM70VA GM85VA |
NACHI | PHV-1B PHV-2B PHV-3B PHV-4B PHV80 PHV-120 PHV-190 PHV80 PHV120 PHV190 PHK1B PHK80 PHK100 PHK120 PHK190 |
EATON | JMV016 JMV018 JMV021 JMV023 JMV041 JMV044 JMV047 JMV053 JMV067 JMV076 JMV118 JMV147 JMV168 JMV155 JMV173 JMV185 JMV274 |
TM SERIES | TM02 TM02E TM03 TM03A TM03CJ TM04 Tm04A Tm04I Tm05 TM06N TM06NK Tm06 TM06K Tm06H Tm06F Tm07 Tm09 TM09E TM09VC Tm18 Tm22 Tm22C |
TM40A Tm40 | |
KAYABA/KYB | MAG-9N MAG-10V MAG-10VP MAG-16N MAG-16V MAG-18V MAG-18VP MAG-26 MAG-33V MAG-37NV MAG-55KP MAG-85NP MAG-85VP MAG-120P MAG-150VP |
MAG-170V |
SANY | SY55 SY60 SY65 SY70 SY75 SY85 SY95 SY115 SY135 SY155 SY195 SY200 SY205 SY215 SY220 SY225 SY235 SY245 SY285 SY305 SY335 SY365 SY375 |
SY395 SY415 SY485 | |
LIUGONG | CLG904 CLG9055 CLG906 CLG907 CLG9075 CLG908 CLG915 CLG150 CLG920 CLG921 CLG922 CLG225 CLG924 CLG925 CLG933 CLG936 CLG939 CLG942 |
CLG948 CLG950 CLG952 CLG200 CLG205 CLG220 CLG225 | |
KUBOTA | KX135 KX185 KX155 KX161 KX163 KX165 KX183 |
IHI | IHI35 IHI50 IHI60 IHI55 IHI80 IHI100 |
XCMG | XE55 XE60 XE65 XE75 XE80 XE85 XE135 XE150 XE155 XE200 XE205 XE215 XE225 XE245 XE270 XE305 XE335 XE370 XE380 XE400 XE470 XE490 |
XE700 | |
YANMAR | ViO35 ViO55 ViO75 |
CX50 CX55 CX58 CX75 CX210 CX240 CX290 CX330 | |
YUCHAI | YC35 YC50 YC55 YC60 YC65 YC85 YC135 YC230 |
JCB | JS130 JS210 JS220 JS290 JS330 |
Final Driving Installation Precautions:
Check the piping and flexible hose is correctly installed. Ensure correct direction of rotation of the motor is achieved.
Check for leakage from all motor parts.
Ensure the system is operating within the specified working temperature.
Check the pressure is operating within specified range.
Diagnosis & Maintenance
• If motor is running with an unusual sound, unscrew the plug from the case drain and check whether the oil level is present. add
the oil level if required and ensure to bleed the trapped air from the circuit. also check the oil quality, if have impurities,
need replace the oil and keep it clean. to keep the life of the Track Drive Motor.
• If you still experience abnormal operation of the motor, check the pressure throughout the work circuit to assess whether or not the motor is breakdown.